Determining the rotary field
direction
The voltage testers feature a two-pole
rotary field direction detector.
Observe safety measures.
The rotary field direction detector is always
active, the LED [
However, the rotary field direction can be
determined only in a three-phase system
between the external conductors. The
instrument displays the voltage between
two external conductors.
Connect the handle test probe (1) to
the presumed phase L1 and the instru-
ment test probe (2) to the presumed
phase L2.
Grip appliance handle completely in the
grip area (11)!
If the presumed external conductor L1 is the
actual external conductor L1, and the pre-
sumed external conductor L2 is the actual
external conductor L2, the right-hand rotary
field is displayed, i.e. the LED for rotary field
[
] (6) is lit.
In the check test with interchanged test
probes the LED for rotary field [
not be lit.
Measurement point illumination
(VP-710, VP-720 only)
The voltage testers feature measurement
point illumination (4) by means of a white
LED. This facilitates work under poor light-
ing conditions (e.g. distributors, control cab-
inets).
To activate the measurement point illu-
mination, press the pushbutton for
measurement point illumination (12)

Maintenance

According to the operating instructions the
voltage testers do not require any special
maintenance for operation. However, if a
malfunction occurs during operation, our
factory service department will test the
instrument immediately.
If the instrument is not used for a pro-
longed period, the batteries must be
removed, as leaking batteries may be
hazardous and cause damage (VP-710,
VP-720 only).

Cleaning

Before cleaning, disconnect the voltage
testers from all measuring circuits. If the
instruments have become dirty due to daily
use, they can be cleaned with a damp cloth
and a little mild household detergent. Never
use aggressive detergents or solvents for
cleaning. After cleaning, do not use the
instrument until it is completely dry.