Becker Centronic SensorControl SC211 Notice De Montage Et D'utilisation page 20

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Assembly and Operating Instructions
Wind
The SC211 detects any vibration in the awning and evaluates it.
The SC211 transmits this value to the receiver.
The receiver compares the value to the threshold (set using a transmitter such
as the SWC241). If the value measured is above the threshold (wind alarm), the
folding-arm awning is retracted immediately.
If this happens, the awning cannot be extended for approx. 15 minutes.
Angle of inclination / Release angle
The SC211 detects a gradual increase or decrease in the awning's angle of in-
clination relative to the initial angle of inclination e.g., due to rain (formation of
water pools). If the awning reaches the release angle, a retract command is sent
to the receiver.
The rotary switch is used to set the release angle between ± 1° and ± 9° in
1° increments.
The factory default is 0 (off).
20
Wind
Release angle e. g., +2°
Initial angle of inclination
Release angle e. g., -2°

Publicité