How to connect the open collector input of the controller
The typical connections of the open collector input of the TV81
Navigator to an external system are described below. Two cases are
considered:
Note that a 24 Vdc, 30 mA voltage, a GROUND signal and the open
collector pin are available on the connector.
Figure 21
Turbo-V 81-AG Navigator Controller User Manual / 87-901-004-01 (G)
1. the customer supplies the 24 Vdc
2. the customer does not supply the 24 Vdc.