PROGRAMMABLE ANALOG SIGNAL: this output signal is a voltage
(from 0 to 10 Vdc) proportional to a reference quantity (frequency or
power or Temperature or Pressure) set by the user. The default
setting is the frequency (see the following example diagram).
Figure 16
Type
Frequency
Power
Temperature
Pressure
Turbo-V 81-AG Navigator Controller User Manual / 87-901-004-01 (G)
10
0
0
Analog Output Voltage proportional to frequency (WIN 111=0)
Range
0 ÷ 1350Hz
0 ÷ 100W
0 ÷ 100 °C
1*10
[Torr] ÷ 1*10
-9
Technical Information
frequency [Hz]
Output Analog Voltage
0 ÷ 10Vdc
0 ÷ 10Vdc
0 ÷ 10Vdc
[Torr]
0 ÷ 10Vdc
-1
17
J1 – IN-OUT
1350
WIN 111
0
1
2
3
163/192