7.6.2 Setting reaction mode for "Aux Out" relay contacts (9)

The factory setting is for the "Aux Out" relay contacts (9) to be activated by the password for the "Aux Out"
relay contacts (9).
You can however activate the relay contacts in different ways. For this purpose, this code lock offers you
convenient options to specify an activation mode.
To set the required activation mode, please enter the following combination:
*
MMMM MMMM
57 C #
C in this case stands for the desired mode type.
Explanation of the various modes:
deactivated
C = 0
enables door monitoring by the "Aux Out" (9) relay contacts*
C = 1
C = 2
enables triggering of the "Aux Out" (9) relay contacts for wrong input of the user password or
master code.
C = 3
enables triggering of the "Aux Out" (9) relay contacts via the "
C = 4
enables triggering of the "Aux Out" (9) relay contacts via the sabotage contact.
allows extended door monitoring **
C = 5
enables triggering of the "Aux Out" (9) relay contacts when the "Lock Out" (h) relay contacts
C = 6
are active.
enables triggering of the "Aux Out" (9) relay contacts via the assigned password (see chapter
C = 7
7.6)
* door monitoring
Behavioural mode: When a user code is entered, the "Lock Out" relay contacts (10) are triggered. If the
magnet contact is opened the "Aux Out" relay contacts (9) are triggered. If the button attached to the "PB"
(5) connection is pressed, the "Lock Out" relay contacts (10) are triggered.
** extended door monitoring
Behavioural mode: When the user code is entered, the "Lock Out" (10) and "Aux Out" (9) relay contacts
are triggered. The "green" LED (4) flashes when the magnet contact is open. If the button connected to the
"PB" connection (5) is activated, the "Lock Out" and "Aux Out" (9) relay contacts are triggered.

7.7 Setting activation period for "AL OUT (-)" (2)

You can set the activation period for the alarm output "AL OUT (-)" (2).
Proceed as follows:
Input example:
*
MMMM MMMM
56 TTT #
Explanation
TTT = 001-999 seconds
*
" button or door bell button (1).
23