• In commercial institutions, the accident prevention regulations of the Employer's Liability Insu-
rance Association for Electrical Systems and Operating Materials are to be observed.
• The code lock is suitable for outdoor use (concealed installation) (IP65).
• Power supply is between 12 - 24 V (AC/DC).
• Make sure that all electrical connections and connection cables between the different de-
vices and any extension cables comply with the regulations and the operating instructions.
• When installing/mounting the device, make sure that the connection cables are neither
pinched nor damaged by sharp edges.
• Maintenance, adjustments and repairs may only be carried out by a qualified specialist or a
specialised repair shop.
• For any unanswered questions please contact our customer service or other specialists.

5. Operating and display elements

4
3
5
2
1
1) Door bell button
Triggers the "Aux Out" relay contract.
2) Keypad
For both programming and code input.
3) LED "red/amber"
Lights up red when the code lock is in operati-
on. Lights up amber in programming mode.
4) LED "green"
Lights up green when the "Lock Out" (10) relay
contacts are active.
5) LED "amber"
Lights up amber when the "Aux Out" (9) relay
contacts are active.