7.7.1 Alarm output "AL OUT (-)" (2) reaction mode
You can trigger the "AL OUT (-)" (2) alarm output in different ways. For this purpose, this code lock offers
you convenient options to specify the activation mode.
To set the required activation mode, enter the following combination:
*
MMMM MMMM
55 C#
C in this case stands for the desired mode type.
Explanation of the various modes:
C = 0
no function
allows the triggering of the alarm output "AL OUT (-)" (2) in connection with the extended door
C = 1
monitoring (also see chapter 7.6.2)
C = 2
enables triggering of the "AL OUT (-)" (2) alarm output via the sabotage contact.
enables modes 1 and 2 jointly.
C = 3
7.8 Restore factory settings (RESET)
When performing a reset, all settings made previously are reset.
• Remove your code lock from the power supply.
• Move the "System Restore" (7) jumper
to the position indicated on the right.
• Reconnect the operating voltage again.
• The internal signaller is now active.
• Move the "System Restore" (7) jumper
to the position indicated on the right.
7.9 Triggering of "Lock Out" relay contacts (10)
Enter the following key combination when you are not in programming mode to trigger the "Lock Out" (10)
relay contacts.
*
UU XXXX
UU is the user's storage position number (01 to 99).
XXXX is the respective user code (4-8 characters).