ENGLISH
5.
Operation
5.1
Operation without hygrostat
The main switch (2) is set to pos.
the main switch lights up. The unit now operates continuously, independently of the relative humid-
ity in the room. The unit is switched off by turning the main switch to pos. 0.
5.2
Operation with hygrostat
The hygrostat plug is connected to the socket, (see 4.3) and the unit is started as described in 5.1.
If the relative humidity of the room is higher than the hygrostat setting, the unit starts to dehumidify.
When the relative humidity of the air is equal to the setting of the hygrostat, the hygrostat will
switch off the unit automatically. The green lamp (2) is still on (see fig. 5.1/5.2). If the humidity of
the air increases again, the unit is switched on again by the hygrostat.
If the dehumidifier is to be turned off completely, for example if the water container is to be emp-
tied, the main switch (2) must be set at pos. 0.
5.3
Emptying the water container
As mentioned in 4.2 the unit has to be switched off
before taking out the water container. When taking
out the water container, press it slightly inwards to
disengage the cut of the water container from the
edge. When reinserting the water container care
must be taken not to place the container in a posi-
tion which switches off the automatic water stop
function (see figure 6).
If the water stop function does not work the water in
the container will run over.
NOTE: After each stop of the unit, either on the main switch, by the hygrostat or by the
water stop function, the electronic control will delay a new start for 45 seconds. This will
protect the compressor against frequent starts and stops.
5.4
Operation with heating element and flexible hoses (Only CDT 35S)
The CDT 35S has a built-in heating element that permits increased outlet temperatures. This is de-
sirable in cases where there is a request for an accelerated dehumidification and drying process at
low room temperatures.
The main switch (2) (see fig. 5.2 for CDT 35S) must be set on
vated on the switch (3).
When the heating element is on, also the light of the switch is on. The heating element now works
continuously and independently of the relative humidity in the room. It is turned off by reactivating
the switch.
-
(see fig. 5.1/5.2) and fan and compressor start. The lamp of
Fig. 6 shows the placing of the water container.
13
-
if the heating element is to be acti-