Transport instructions
Always transport the CDT 22 in vertical position. If the unit is laid down during transport, the com-
pressor may be damaged and oil from the compressor may get into the cooling circuit.
These precepts do not apply for CDT 35, CDT 35S, CDT 50 and CDT 85, as these units are fitted
with rotary compressors.
If the units CDT 35, 35S, 50 or 85 have been laid down during transport, they must stand in
vertical position for at least 1 hour, before they are put in service.
4.
Placing of the unit
If possible the dehumidifier should be placed in the middle of a room to ensure a good air circulation.
The air should be sucked in freely at the back of the unit and blown out at the front.
The minimum distance from a wall should be about 60 cm. The minimum distance on the exhaust
air side should be 3 metres.
It is important that the dehumidifier is not installed near a source of heat as for example a radiator,
and doors and windows must be kept closed.
4.1
Electrical connection
The unit is complete with plug and cable and ready for connection to a 230V/50Hz socket. The
socket should be fuse protected with a 10A fuse or a 16A circuit breaker.
NOTE : Observe local power supply company regulations !
Figuer 3 shows the placing of the unit in relation to a wall