EEPROM WRITING
ERROR
Selecting a particular spot memory in which you have stored data
-
Select "Manual" with the "MAN" button.
-
Select MEMORY SELECT with the "+" button.
-
Press the "ENTER" button.
-
Select the desired spot memory with the "+" or "-" button.
-
Confirm with the "ENTER" button.
-
Select "START" with the "-" button.
-
Confirm with the "ENTER" button.
-
If necessary change mode to CHARGE or DISCHARGE and DISC-CHAR using the
Mode button.
-
Start the process by operating the "START" button.
General information about charging and discharging batteries
As a basic rule please be sure to observe the battery manufacturer's recommendations,
especially the information regarding maximum charge currents.
To ensure that the automatic Delta Peak circuit is able to work as efficiently as possible,
only properly balanced packs should be fast-charged. This means that new packs, and
packs which have not been used for a long time, should be discharged at regular intervals
and re-balanced by slow-charging at a low rate, typically C/10.
An occasional complete discharge process also helps to avoid and/or eliminate the
MEMORY EFFECT.
Fairly old batteries, and packs of certain relatively low-quality cells, may prevent the auto-
matic current setting function working properly in automatic mode. In such cases we recom-
mend that you use manual mode.
Charging and discharging a transmitter battery which is installed in the RC system trans-
mitter is only possible if you either by-pass the protective diode in the transmitter's charge
circuit, or remove the battery from the transmitter and connect it to the charger using a
direct charge lead.
Conversion work on the transmitter should only be carried out by an expert, ideally by your
nearest robbe Service Centre.
Recommended direct charge leads
No. 8262
F-series transmitter
No. 8263
International series
Operating instructions
POWER PEAK ULTIMATE
Problem with internal memory. If the problem recurs, consult
the robbe Service Centre.