EXIT
SOUND
START
MEMORY SELECT
CHARGE
START
0 ] NICD 21 CL
Spot memory
C 298mAh 0 : 05 : 29
31 . 55V 3 . 80A
-
The charge or discharge process is ended by the automatic termination circuit or by the
operator pressing the STOP button.
-
When you next connect the charger to its power supply, the unit automatically reverts to
the spot memory you last used.
Auxiliary functions
Adjusting the current during charging or discharging (manual mode only)
CHARGE CURRENT
4 . 5A
Use the + / - buttons to change the current during charging or discharging.
Additional information
Access via double button function (press + and - buttons simultaneously); leaf through with
the + or - buttons.
IN/OUT VOLTAGE
11 . 950 Vi 31 . 550 Vo
CHARGE VOLTAGE
30 . 075 Vp 30 . 075Va
DISCH. VOLTAGE
27.300Vs 16.800Vc
Operating instructions
POWER PEAK ULTIMATE
At the EXIT menu point you can jump to the "AUTO /
<-
MANUAL" select option with the ENTER button; under
OFF
SOUND press the ENTER button to activate or disable the
buzzer.
<-
To initiate the charge or discharge process confirm the
0
START menu point with the ENTER button.
You can now press the MODE button to select CHARGE,
DISCHARGE or DISC-CHAR.
1800
Start the charge or discharge process by pressing the START
button.
The screen displays capacity, time, voltage and current. The
charger's status (C=CHARGE, D=DISCHARGE, F=FINIS-
HED) is displayed at top left of the screen.
DISCHARGE CUR.
2 . 5A
Input and output voltage
Peak and momentary voltage
Discharge voltage at start or end of the discharge process.