Marking
The variable codes given in the following table are used for the marking of the
electrical connection variants. For the connection types with supply lines /
cable line, the variable code is dependent on the length of the line.
E.g.: The variable code JW04 corresponds to a line length of 500 mm
Electrical connection variants
- Supply line / cable line
- Terminal box with M 20 x 1.5 cable gland, without fuse
- Terminal box with M 20 x 1.5 threaded nipple, without fuse
- Terminal box with NPT ½ threaded nipple, without fuse
- Terminal box with G ½ threaded nipple, without fuse
- Terminal box with M 20 x 1.5 cable gland and fuse
- Terminal box with M 20 x 1.5 threaded nipple and fuse
- Terminal box with NPT ½ threaded nipple and fuse
- Terminal box with G ½ threaded nipple and fuse
NOTE
Connection types with terminal box
Available with / without unit protective fuse
(Unit protective fuse according to separate EC Qualification Test
Certificate)
ATTENTION
•
Only permanently laid cables and wiring may be inserted.
•
The operator must provide suitable stress relief.
•
Wires with an outside diameter of 6 to 13 mm may be used.
Observe the maximum thermal loading of the cables or
wires to be inserted.
•
The inserted break-off seal must be matched to the
diameter of the cable or wire.
•
The rated cross-section of the cable or wire strands must
be at least 0.75 mm² and may not exceed 2.5 mm².
•
The screws for fixing the cover of the terminal box must be
tightened with a torque of 100 Ncm (±5%).
Variable code
dependet on the
line length
JA02
JA08
JA09
JA10
JA01
JA05
JA06
JA07
03 ATEX5014 X - 15