Technical data for the type 6013 and 6022 units
Temperature class
Electromagnet used
Circuit function of
the valve
Type of current
Rated voltage
Rated current
Power limit at steady
state
Maximal permissible
ambient temperature
range
Single mounting
Type of protection
Electrical connection
Type of protection /
Marking of the
magnetic coil
Type of protection /
Marking of the
complete unit
NOTE
Only individual mounting is permissible for units of the
types 6013 and 6022.
14 - 03 ATEX5014 X
Type AC10 with Approval No. PTB 00 ATEX 2129X
A = normally closed
Universal current (0 Hz to 60 Hz)
12 V - 400 V (± 10 %)
Coil size 5
0.68 ....0.02 A
Coil size 5
7 W
Coil size 5
PD47: -30 °C up to +60 °C
PD60: -40 °C up to +60 °C
IP 65 according to EN 60529 (DIN VDE 0470 Part 1)
Electrical connection variants according to approval of the
Type AC 10 electro-magnets with No. PTB 00 ATEX 2129X
(see following description).
The type of protection changes depending on the electrical
connection variants (the components used):
II 2G EEx m II T4 or II 2G EEx em II T4
(see following description)
The marking changes depending on the electrical connection
variants (the components used):
II 1 / 2 G EEx m II T3 or II 1 / 2 G EEx em II T3
(see following description)
T3
Coil size 6
0.8 .... 0.02 A
Coil size 6
9 W
Coil size 6
PD53: -30 °C up to +60 °C
PD66: -40 °C up to +60 °C