Chimney Draught; Air Supply - Nordpeis Bergen Manuel D'installation

Masquer les pouces Voir aussi pour Bergen:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INDEX
1. Prior to assembling the stove
Some advice in case of combustion problems
16
1. Prior to assembling the stove
All our products are tested according to the latest
16
European requirements and also to the Norwegian
16
standard NS 3058 and NS 3059, which include particle
16
tests. However, several European countries have local
17
regulations for installation of fireplaces, which change
17
regularly. It is the responsibility of the client that these
regulations are complied with in the country/region
17
where the fireplace is installed. Nordpeis AS is not
17
responsible for incorrect installation.
17
17
Important to check
17
(please note that this list is not exhaustive):
18
distance from firebox to combustible/flammable
materials
18
insulation materials/requirements between
18
fireplace surround and back wall
18
size of floor plates in front of fireplace if required
18
flue connection between firebox and chimney
18
insulation requirements if flue passes through a
19
flammable wall
19
19
Compared with older models, the clean burning inserts
of today put significantly higher demands on the
chimney. Even the best insert will not work properly
21
if the chimney does not have the right dimensions or
is not in good working order. The draught is mainly
controlled by gas temperature, outside temperature, air
supply as well as the height and inner diameter of the
chimney. The diameter of the chimney should never
be less than that of the flue/chimney collar. At nominal
effect there should be a negative pressure of 12 to 25
Pascal.
The draught increases when:
The chimney becomes warmer than the outside air
The active length of the chimney over the hearth
increases
Good air supply to the combustion
It can be difficult to obtain the right draught conditions
in case the chimney is too large relative to the insert,
as the chimney does not heat up well enough. In
such cases you may want to contact professional for
evaluation of possible measures. Draught that is too
strong can be controlled with a damper. If necessary,
contact a chimney sweeper.

Air supply

A set for fresh air supply is available as accessory.
This will ensure that the air supply to the combustion
chamber is less affected by ventilation systems,
kitchen fans and other factors which can create a
down-draught in the room. In all new construction, we
strongly recommend that it is designed and prepared for
direct supply of outside air. In older houses, the use of
fresh air supply set is also recommended. Insufficient
air supply can cause down-draught and thereby low
combustion efficiency and the problems that this
entails: soot stains on the glass, inefficient use of the
wood and a soot deposits in the chimney.