Prior To Assembling The Insert; Chimney Draught; Floor Under The Fireplace - Nordpeis NI-22 Manuel D'installation

Masquer les pouces Voir aussi pour NI-22:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22
INDEX
EC CONFORMITY DECLARATION
Date of issue: 15.09.2009
Conformity declaration issued by:
Company name:
Address:
Postal:
Country:
Phone:
Identification:
Product type:
Fireplace insert
Insert type:
Cast iron fireplace insert burning solid fuel
Fuel type:
firewood only - see manual
Flue gas temperature:
310 ºC
CO content at 13 % O
:
0,08 %
2
Thermal output, nominal value:
6,0 kW
Energy efficiency:
78,2 %
Safety measurements:
Only to be used in non-combustible surrounds.
Must be used in accordance with user manual.
Minimum distance to adjacent
combustible materials:
Must be placed in accordance with user manual.
Country
Classifications
Test standard
EUR
Intermittel
Stian Varre
General manager, Nordpeis AS
Rapport Nr. RRF - 29 09 1917
Inspection code: 1625
Rhein-Ruhr Feuerstättenprüfstelle GmbH
Am Technologiepark 1, D-45307 Essen
10
10
All manuals and user guides at all-guides.com
10
10
10
11
11
11
12
12
12
12
12
12
12
13
13
13
14
15
Nordpeis AS
Gjellebekkstubben 9/11
N-3420 Lierskogen
Norway
(+47) 32 24 47 00
(+47) 32 24 47 11
www.nordpeis.no
post@nordpeis.no
Approved by
EN 13229
RRF

1. Prior to assembling the insert

Our surrounds are all made of non-combustible
materials. All our inserts/stoves are tested according
to the latest European requirements and also to the
Norwegian SINTEF standard, which includes particle
tests. Several European countries however have
individual rules for installation of inserts, stoves and
fireplaces.
The client is entirely responsible for the fulfilling of
these local rules concerning the installation in his
region/country. Nordpeis (Northstar) is not responsible
regarding correct installation. You should check local
regulations concerning: distance from firebox to
combustible/flammable materials, insulation materials/
requirements between fireplace surround and back
wall, size of floor plates in front of fireplace/stove if
required, fluepipe connection between firebox and
chimney and insulation requirements if fluepipe goes
through inflammable wall such as a wooden wall.
For your own safety, comply with the user
manual. All safety distances are minimum
distances. Installation of the insert must
comply with the rules and regulations of the
country where installed. Nordpeis AS is not
responsible for wrongly assembled inserts.

Chimney Draught

Compared with older models, the clean burning
inserts of today put significantly higher demands
on the chimney. Even the best insert will not work
properly if the chimney does not have the right
dimensions or is not in good working order. The
draught is mainly controlled by gas temperature,
outside temperature, air supply as well as the height
and inner diameter of the chimney. The diameter of
the chimney should never be less than that of the flue/
chimney collar. At nominal effect there should be a
negative pressure of 14 to 25 Pascal.
The draught increases when:
The chimney becomes warmer than the outside air
The active length of the chimney is increased (over
the hearth)
Good air supply to the combustion
It can be difficult to obtain the right draught conditions
in case the chimney is too large in relationship to
the fireplace, as the chimney does not heat up well
enough. If possible, insert a smaller chimney pipe.
Draught that is too strong can also be controlled with
a damper.

Floor under the fireplace

Ensure that the floor where the fireplace is placed
can withstand the load with regards to the total weight
of the fireplace. If unsure, contact the local building
authorities or a builder for review / approval. When
mounting the fireplace on a floating wooden floor, the