INDEX
EC CONFORMITY DECLARATION
Date of issue: 16.09.2008
Conformity declaration issued by:
Company name:
Address:
Postal:
Country:
Phone:
Fax:
Web:
E-mail:
Identification:
Product type:
Stove type:
Fuel type:
Flue gas temperature:
CO content at 13 % O
:
2
OGC content at 13 % O
:
2
Thermal output, nominal value:
Energy efficiency:
Safety measurements:
Minimum distance to adjacent
combustible materials:
Country
Classifications
EUR
Intermittel
General manager, Nordpeis AS
Nordpeis AS
Gjellebekkstubben 9/11
N-3420 Lierskogen
Norway
(+47) 32 24 47 00
(+47) 32 24 47 11
www.nordpeis.no
post@nordpeis.no
Nordpeis SMARTY
Stove room heater
Welded iron stove burning solid fuel
Firewood only, see manual
306 ºC
0,07 %
76 mg/m³
5,0 kW
81,2 %
Must be used in accordance with user manual
Must be placed in accordance with user manual.
Test standard
Approved by
EN 13229
RRF
Stian Varre
Rapport Nr. RRF - 40 09 1921
Inspection code: 1625
Rhein-Ruhr Feuerstättenprüfstelle GmbH
Am Technologiepark 1, D-45307 Essen

1. Prior to assembling the stove

9
All our products are tested according to the latest
9
European requirements and also to the Norwegian
9
SINTEF standard, which includes particle tests.
Several European countries however have individual
10
rules for installation of inserts, stoves and fireplaces.
10
The client is entirely responsible for the fulfilling of
these local rules concerning the installation in his
10
region/country. Nordpeis (Northstar) is not responsible
10
regarding correct installation. You should check local
10
regulations concerning: distance from firebox to
10
combustible/flammable materials, insulation materials/
10
requirements between stove and back wall, size
11
of floor plates in front of stove if required, fluepipe
connection between stove and chimney and insulation
11
requirements if fluepipe goes through inflammable
11
wall such as a wooden wall.
11
11
11
For your own safety, comply with the user
manual. All safety distances are minimum
12
distances. Installation of the stove must
12
comply with the rules and regulations of the
country where installed. Nordpeis AS is not
responsible for wrongly assembled stoves.
13

Chimney Draught

Compared with older models, the clean burning stoves
of today put significantly higher demands on the
chimney. Even the best stove will not work properly
if the chimney does not have the right dimensions or
is not in good working order. The draught is mainly
controlled by gas temperature, outside temperature,
air supply as well as the height and inner diameter
of the chimney. The diameter of the chimney should
never be less than that of the flue/chimney collar. At
nominal effect there should be a negative pressure of
14 to 25 Pascal.
The draught increases when:
The chimney becomes warmer than the outside air
The active length of the chimney is increased (over
the hearth)
Good air supply to the combustion
It can be difficult to obtain the right draught conditions
in case the chimney is too large relative to the stove,
as the chimney does not heat up well enough. If
possible, insert a smaller chimney pipe. Draught that
is too strong can also be controlled with a damper. If
necessary, contact a chimney sweeper.

Air Supply

A set for fresh air supply is available as an accessory,
and will ensure that ventilation systems, kitchen fans
and other factors that can create a downdraught in
the room of the stove affect less the air supply to the
stove. Insufficient air supply can cause downdraught
and thereby low combustion efficiency and the
problems that this entails: soot stains on the glass,
inefficient use of the wood and a soot deposits in the
chimney.