3.

PROGRAMMING

3.1

PROGRAMMING DOSES

To enter the programming mode, proceed as follows:
NOTE: the procedure can be carried out with the
machine on.
To enter the dose programming mode, it is
necessary to press and hold down the continu-
ous dispensing key
for 5 sec.
The delivery keys will begin to flash.
3.2
COFFEE DOSE
PROGRAMMING
To programme the amount of water for each of the
delivery keys, proceed as follows:
fill the filter holder with the right amount of cof-
fee (the double or single filter holder can be
used, according to the key to be programmed).
Place the filter holder in the group.
Press one of the delivery keys:
Dispensing will commence; once the required
quantity has been poured, press the same key
again.
Press the
key to quit the programming
mode.
24
3.3
PROGRAMMING HOT
WATER
Use the relevant procedure to enter the pro-
gramming function.
Press the hot water selection key
Hot water delivery will begin.
Decide the required amount of hot water and
then press the key
again.
Press the
key to quit the programming
mode.
3.4
PROGRAMMING
STANDARD DOSES
It is possible to enter pre-set values for the
group doses and hot water.
To do this, it is necessary to press the key
and hold it down for at least 10 seconds
until the flashing keys switch off.
The doses are:
1CN
2CN
CONT.
80 cc
120 cc
160 cc
NOTE: Setting a time of 0 seconds for the water
causes it to operate in continuous mode.
3.5

ADDITIONAL FUNCTIONS

Also within the programming function (while no pour-
ing is in progress), pressing the "
.
then holding it down and pressing the "
opens the page for setting the parameters:
1.
Software block activation to enter the
dose programming mode.
2.
Keypad brightness adjustment.
3.
Dose pre-infusion activation.
The
key serves to enable the software
block to enter the dose programming mode (key
lit) or disenable it (key off). To remove a soft-
ware block for programming, it is necessary to
quit the dose programming mode and follow
these steps: from OFF status, switch the control
unit to ON and as soon as the Lamp-test
begins, release the
and
down until the Lamp-test is complete.
The
key, which flashes, is used to
choose the brightness of the keys from the 9
WATER
45 sec.
pre-set levels. Pressing the
reduce the brightness setting as far as mini-
mum, to then start again from the maximum
value.
Pressing the
sion (approx. 3 sec.) for dispensing (key lit) or it
will switch it off (key off).
Pressing the
ting functions and return to the dose programming
mode.
" key and
",
key and press the
keys together, holding them
key will
key will start the pre-infu-
key will quit the parameter set-