Thetford Marine TECMA Nani Premium PLUS Manuel D'installation Et D'utilisation page 36

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Correct Water Level Usage
■ Water usage is not adjustable in the Marine Mode.
■ The recommended water level in the Residential Mode is 5" below the toilet rim. To set this in
the programming mode, release your fingers
4-5 seconds after water begins flowing into the toilet. Setting the water deeper than this level
creates excessive water use and fills the holding tank too quickly.
CAUTION:
Raw Water systems are designed to perform optimally with pumps rated at approximately 3.0 Gallons per Minute (similar to the pump
supplied). Lower rated pumps will provide a less vigorous fl ush, while use of higher-rated pumps will cause excessive water consumption.
Bowl Emptying
■ To empty bowl without adding water or starting a flush sequence, push and hold both buttons simultaneously until bowl contents are discharged. Pushing either button
returns toilet to normal operation.
CAUTION!
Refi ll the toilet as soon as possible after emptying the bowl. Leaving water out of the plumbing trap can result in objectionable odors.
Flush Lockout
■ This toilet is equipped with an electronic holding tank level sensing feature that automatically prevents FLUSH button operation when the holding tank is full and, thus,
prevents waste overflow.
Single Flush Override of Flush Lockout
■ If holding tank is full, system will not allow a flush to occur. (If a flush is taking place, it will be completed.) This can be overridden by holding the FLUSH button for about 8
seconds.
■ This override function is intended for emergency use only. Because the sensor is not located at the exact top of a tank, the override function can be used about 5 times
before overflowing. Size and shape of the holding tank determine the actual number of times it can be used. Contact manufacturer for more detailed information.
WARNING:
An excess of fl ushes after fl ush lockout is disabled can cause waste to overfl ow tank through plumbing.Tecma accepts no responsibility
or liability for damage to equipment, or injury or death for overfl ow of waste holding tank when full-tank lockout is overridden. Waste holding tank should be
checked after using Nano in override mode.
Tecma Nano PREMIUM Owner's & Installation Manual
Empting the Bowl
Simultaneously press and
release
(0.5<, <3.0 sec.)
NOTE:
Holding more than 5 seconds
will start the water level programming
mode.
{
The toilet empties but no water is added
{
Pushing either button will activate its normal
function.
36
www.thetfordmarine.com

Publicité