Santiago 2
English
• the cabinet is in defrosting
The cabinet
phase
does not cool
• air inlets are obstructed
sufficiently
• the load is not distributed even-
ly
• the cabinet is next to air cur-
rents or heat sources
• the cabinet is not levelled
• screws and bolts are not tight-
The engine is
noisy
ened
• the cabinet is not levelled
• poor room conditions
Condensate
• poor air ventilation
• the window heaters do not work • check electrical connections
• the windows are not closed
properly
• poor room conditions
Cabinet
temperature
is too high or
• output air temperature is out-
too low
side the specified range
• the cabinet is defrosting.
• the capacitor or the evaporator
are freezing.
• the capacitor or the evaporator
are obstructed or dirty.
• the load is not distributed even-
ly
• cabinet drains are obstructed or
Water leaks,
bad smell
damaged
• water collection tray is sealed
incorrectly
• water collection tray overflows • check wiring of evaporation heater
• insufficient joints between cabinets
in channel or joints not sealed cor-
rectly
in the cabinet
Frost or ice
• the fans are not working in the
evaporator
• heating elements broken
• Sdef probe detached
• air currents that alter the circu-
lation of refrigerated air
i
in all cases not described or where it is not possible to solve the problem by following these
directions call the nearest authorised after-sales centre.
52
• wait for defrosting to complete (about 30min)
• release air inlets
• load the goods in an orderly fashion (Fig.15)
• check the position of the cabinet inside the
store chap.12
• level the cabinet see chap.12
• tighten the bolts and screws
• level the cabinet chap.12
• check the position of the cabinet inside the
store chap.12
• check the operation of fans and wiring
• check the operation of heating elements
• close the windows properly
• check the position of the cabinet inside the
store chap.12
• check the operation of evaporator fan
• check wiring and input voltage
• the fans are installed reversely; check and re-
store the air flow direction
• check that fan plenum is sufficient and not
obstructed
• check the intake pressure that should comply
with rated specifications
• check defrosting parameters
• check that the suction line is not obstructed
• proceed with cleaning
• load the goods in an orderly fashion (Fig.15)
• free the drain
• repair or replace the drains
• seal it properly
• check the operation of evaporation heater
• install and seal the joints
• check electrical connections
• check the ventilation inside the store