Electrical installation
Wiring

Operation with another supplier

4.4.2
Operation with another supplier
(
Stop!
ƒ
ƒ
ECSx : X6/SI1
ECSxK: X26 (24 V DC)
Fig. 4−3
Level/time diagrams for operation with other supplier
ECSxü
U
ECSxK
K1
56
After mains connection, wait at least one second before bridging
the charging current limitation (X26 = HIGH).
Only release the controller (X6/SI1 = HIGH) if the charging
current limitation is bridged.
HIGH (1)
ü
LOW (0)
100 %
U
ZK
0 %
HIGH (1)
LOW (0)
HIGH (1)
K1
LOW (0)
Axis module of the ECS series
DC−bus voltage
DCbus
Capacitor module of the ECS series
Mains contactor
1
l
t [s]
t [s]
t [s]
t [s]
ECSXK011
EDKCSEK002 DE/EN/FR 3.0