4
Electrical installation
Wiring
Operation with ECSxE power supply module
4.4
Wiring
Install the capacitor module between the power supply module and the axis
module(s).
If the total cable length in the DC−bus connection is longer than 5 m, install the
capacitor module as close as possible to the axis module with the highest
power.
4.4.1
Operation with ECSxE power supply module
(
Stop!
ƒ
ƒ
ECSx : X6/SI1
ECSxE: X6/DO1
ECSxK: X26 (24 V DC)
ECSxE: X6/DI1
ECSxE: X6/DI2
Fig. 4−1
Level/time diagrams for operation with ECSxE power supply module
ECSxü
ECSxE
U
ECSxK
K1
54
Permanently bridge the charging current limitation (X26) of the
capacitor module (X26 = HIGH).
Only release the controller (X6/SI1 = HIGH) if the power supply
module ECSxE displays "Ready for operation" (X6/DO1 = HIGH).
HIGH (1)
ü
LOW (0)
100 %
U
ZK
0 %
HIGH (1)
LOW (0)
HIGH (1)
K1
LOW (0)
Axis module of the ECS series
Power supply module of the ECS series
DC−bus voltage
DCbus
Capacitor module of the ECS series
Mains contactor
l
t [s]
t [s]
t [s]
t [s]
ECSXK010
EDKCSEK002 DE/EN/FR 3.0