2.2
Rated data
Rated data
Data for operation with upstream
supply module on mains voltage
DC−bus voltage
Rated AC current
Rated power
Rated power with mains choke
Capacity
Time constant for charging the
capacitors
Charging time after mains connection
Weight
ECSEKxxx
ECSDKxxx
ECSCKxxx
Dimensions
ECSEKxxx
ECSDKxxx
ECSCKxxx
EDKCSEK002 DE/EN/FR 3.0
Type
ECSxK001xxx
U
[V]
400
mains
U
[V]
DC
I
[A]
r
P
[kW]
B
P
[kW]
BN
C [mF]
705 (±20 %)
[ms]
t
[s]
C_charging
m [kg]
m [kg]
m [kg]
(W x H x D)
88.5 x 247 x 176
[mm]
(W x H x D)
88.5 x 247 x 176
[mm]
(W x H x D)
88.5 x 282 x 123
[mm]
l
Technical data
Rated data
ECSxK002xxx
480
400
0 ... 770
17,5
10
14
1410 (±20 %)
150
1
2.1
2.1
2.4
132 x 247 x 176
132 x 247 x 176
132 x 282 x 123
2
480
35
20
28
3.2
3.2
3.4
43