Control System; Flow Switch; Product Solenoid Valve; Preventive Maintenance - Ecolab Hybrid Foamatic MA2CM Mode D'emploi

Table des Matières

Publicité

9.2.2.

Control system

Maintenance free.
If defective: Call a service technician.
9.2.3.

Flow switch

Maintenance free.
If defective, replace the flow switch.
1. Press "
" on the control display to stop the
system.
2. Remove the cover.
3. Turn the "rinse/foam" handle to foam position.
4. Activate the spray handle on the outlet hose so
water runs out.
5. Check that the flow switch is turned the correct way
(the wire must follow the follow direction).
6. Turn the brass screw at the bottom of the hole until
a green diode lights up.
7.Close the spray handle again and check that the red
diode lights up.
8. Mount the cover.
9.2.4.

Product solenoid valve

Maintance free.
If defective, replace the product solenoid valve and/or
replace chemical supply hoses.
Warning: Risk of chemical residue.
Wear protec tive gear.
1. Turn off power supply.
2. Remove valve with a slot-head screwdriver.
3. Change valve and/or hoses. Be ware of flow
direction marked on bracket.
4. Mount the valve in the bracket.
The flow direction is marked on the
bracket. The flow of chemical supply is
in the direction of the arrow with the tip
pointing towards the automatic block.
Do NOT use the marking printed on
the solinoid valve.

9.3. Preventive maintenance

Depending on usage, maintenance should be un-
dertaken by an authorised service engineer at least
once a year in order to prevent defects and failure of
operation. Authorised engineers are persons who due
to their skills and experience have sufficient knowl-
edge of the Hygiene Systems and are confident with
the state work safety regulations, accident preventing
regulations, lines and generally acknowledged techni-
cal regulations such as DIN-norms and VDE-provi-
sions. For your safety, this cleaning unit has been
manufactured according to all relevant regulations
valid in the EU and therefore it has been supplied with
the CE-marking. For further information, please refer
to the service department.

9.4. Rinsing the chemical supply/injector system

The chemical supply must always be
rinsed thoroughly after use.
Remains of detergents or disinfectants can clog the
injector so it needs to be rinsed or replaced.
The following procedure will clean the chemical sup-
ply for detergents and/or remains of disinfectants.
1. Remove User Pack, if any.
2. Hold the rinsing bottle with clean water tightly
against the suction opening (with User Pack) or
against the hose (without User Pack). Alternati-
vely, you can place a User Pack with clean water
in the holder or – without User Pack – place the
hose in a bucket of clean water.
3. Activate the hose handle until clean water comes
out of the nozzle (approx. 30 seconds).
This procedure should be
followed both on the detergent
and the disinfectant side (if this is
installed).

9.5. Change of injector

1. Turn off power supply.
2. Turn off water and air supply.
3. Depressurise the system.
4. Unscrew and change injector. Beware of chemi-
cal residue.
5. Reconnect water, air supply and power supply.
WARNING
Risk of chemical residue.
Wear protective clothing.
CAUTION
The unit might be hot.
Ensure sufficient cooling time.

9.6. Deliming

The interval of the deliming procedure depends on
the water hardness. Please see table in the end of
this section.
23