9.6.1.

Manual block

1. Make sure the water and the power to the unit is
disconnected.
2. Remove the cover from the unit.
3. Depressurise the system.
4. Dismount the injector block, product non-return
valve, air valve and air non-return valve including
the air fittings.
5. Rinse the injector block in the clean water.
6. Place the injector block and product non-return
valves in a deliming bath - make sure the selector
knob is over the surface.
7. Wait for 60 minutes.
8. Rinse the injector block in clean water.
9. Mount the air valve, air non-return valve and
product non-return valve on the injector block
and mount the injector block in the unit.
10. Reconnect water to the unit.
11. Test the unit in foam position make sure the
vacuum is sufficient, it is recommended to be
between 14,8-20,7 inHg/-0,05-0,07MPa.
12. Test that the unit can start and stop in both foam
and rinse position.
13. Reinstall the cover on the unit.
9.6.2.

Automatic block

A dedicated deliming program is needed for the fol-
lowing process:
1. Remove the cover from the unit.
2. Place the chemical supply hoses in clean water
and activate the foaming function on all chemical
valves for 1 minute.
3. Place the chemical hoses in deliming fluid and
activate the foaming function for all chemical
valves for 1 minute.
4. Wait 60 minutes.
5. Place the chemical hoses in clean water and ac-
tivate the foaming function on all chemical valves
for 5 minutes.
6. Activated the rinsing function for 1 minute.
7. Test foaming function and make sure the vacuum
is sufficient, it is recommended to be between
14,8-20,7 inHg/-0,05-0,07MPa.
8. Reinstall the cover on the unit.
°dH
ppm
Time between deliming
0-5
18-90
12 months
5-10
90-180
6 to 12 months
10-15
180-270
3 to 6 months
15-20
270-360
3 to 6 months
>20
>360
1 to 3 months
24

9.7. Coupling

It is recommended to lubricate all coupling parts regu-
larly (approx. once a week) with waterproof grease
to prevent leaks and damage of o-ring. If the unit
is equipped with a spray gun the -o-ring of the gun
should also be lubricated.
In leaking quick couplings the o-rings should be
replaced.

9.8. Internal cleaning of the unit

Depending on the environment where the unit is in-
stalled, internal cleaning of the unit might be required.
We recommend opening and cleaning the unit inside
once a year. Do not spray inside the unit.
Chemical hoses; it is recommended to check all
chemical hoses regularly, approx. once every 3rd
month.
Table 9.1