Faults With The Device - Fronius TIG Grinder Instructions De Service

Instrument de rectification pour électrodes en tungstène
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Faults with the
The separator does not cut
device
The electrode is not cut through or is only partially cut
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Grinding fluid is escaping
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
The digital display is not showing anything
Cause:
Remedy:
Cause:
Remedy:
Electrode was not turned enough during cutting
Turn the electrode several more times at the end of the cutting process
Cutting wheel is worn out
Change the cutting wheel
The drive belt is faulty
Contact After-Sales Service
Drain hose is not sealed
Seal the tank drain hose and attach it in the collecting cup on the left side of
the device
The seal between the viewing window and the housing is leaking
Drain the grinding fluid; remove the housing cover; clean or change the seal
The tank seal is leaking
Drain the grinding fluid; remove the tank; clean or change the seal
The battery in the digital display is flat
Change the digital display battery
The digital display is faulty
Contact After-Sales Service
63

Publicité

Table des Matières
loading

Table des Matières