ATTIX 110
Recommended spare parts
The following is a list of spare parts that should be kept ready at hand in order to speed up maintenance
operations.
List of recommended spare parts (fig. 17)
Pos.
A
B
C
D
E
Troubleshooting
Problem
The vacuum cleaner suddenly
stops
Dust leaks from the vacuum
cleaner
Electrostatic current on the
vacuum cleaner
Liquid leaks from the vacuum
cleaner
The vacuum cleaner does not
start after emptying the container
Manufacturer Service Centre
Please consult the appendix.
GB
Part
Filter
Filter ring
Filter ring gasket
Filter clamp
Single-phase motor 000 W
Clogged main filter
Clogged vacuum hose
Circuit breaker activation
The filter is torn
Non existent or inefficient
grounding
The level monitoring function does
not work
The level monitoring hose is
clogged
Dimension
Ø 460
Ø 460
Ø 460
Ø 460
Cause
Shake the filter. Replace it if necessary
Check the vacuum hose and clean it
Check the setting
Check the motor electrical input
Empty the container
Contact an authorized Service Centre if
necessary.
Replace the filter
Check all grounding, particularly the
union to the inlet; moreover, the hose
must be strictly antistatic
Contact an authorized Service Centre
Release the container and clean the
level sensor
-2-
Code
8 774
8 5003
8 7026
8 8079
8 54002
Remedy