Separator cleaning and replacement - if
equipped
See fig. 14.
Note
If there is only a dust deposit on the separator "A",
allow the dust to drop through the central hole.
The separator "A" should first be disassembled in order
to be perfectly cleaned:
-
Use the levers "B" to remove the head "C"
together with the filter.
-
Unscrew the two screws "D" and remove it from
the container.
Replace the part if it is excessively worn.
Assemble the components in the reverse order of
disassembly.
Vacuum cleaner disposal
Dispose of the vacuum cleaner in compliance with the
laws in force.
Proper disposal (electric and electronic waste)
(applicable in the European Union and in countries
providing a separate collection system)
The above symbol "M" (fig. 1), which is present on the
product or o in its documentation, indicates that the
product can not be disposed of with other domestic
waste at the end of its cycle of life. To prevent
damages to the environment or the health caused by
improper waste disposal, please separate this product
from other waste and recycle it responsibly in order to
support the sustainable reuse of material resources.
Domestic users should contact the retailer or the local
office providing information on separate collection and
recycling of this product. Companies should contact
the supplier and check the purchase contract terms
and conditions. This product can not be disposed of
together with other commercial waste.
Wiring diagrams
Basic vacuum cleaner wiring diagram (fig.15)
Wiring diagram list
Name
J
Anti-jamming filter
H
Voltage plate indicator
S-S2-S3
Motor switches
M-M2-M3
Motors
Wet vacuuming kit wiring diagram (fig.16)
Name
Circuit breaker
Q
Handle for Q
B
Auto release
PR
Pressure switch
--
ATTIX 110
ATTIX 110
Part
Code
8 39533
8 3905
8 39000
8 54002
Part
Code
8 3904
8 39954
8 3955
8 4084
GB