BATTERY INSTALLATION/REMOVAL AND BATTERY TYPE SETTING (WET OR GEL-AGM)

WARNING!
Do not tilt the lead batteries (WET) to prevent the highly corrosive acid from leaking out of the batteries. Do not
connect, not even accidentally, the battery positive and negative terminals by using tools, keys, etc. This could
cause dangerous short-circuits.
Battery Installation
For approved battery types, see the Technical Data paragraph.
According to the battery dimensions, check if it is possible to
place them inside the relevant plastic container, supplied with
the machine.
If the batteries are larger than the container, use the square
guides, supplied with the machine, to ensure the stability inside
the battery compartment.
WARNING!
Non-sealed WET batteries always need an
appropriate container to prevent the acid form
leaking.
Do not install the WET batteries without an
appropriate container.
1.
Engage the parking brake.
2.
Check that the ignition key (51) has been removed.
3.
Open the battery compartment hood (19) and fasten it with
the support rod (47).
4.
Disconnect the battery connector (45).
5.
With the help of an appropriate hoisting system, install the
batteries (42).
6.
Connect the batteries according to one of the diagrams
shown in figure 2, on the basis of their type.
7.
Connect the battery connector (45).
8.
Set the battery type (WET or GEL-AGM), according to the
following procedure.
Battery Setting (WET or GEL-AGM)
1.
Start the machine by turning the ignition key (51) to "I",
while holding down push-buttons (52) and (53).
2.
Enter the "Parameters" menu by pressing the push-button
(60).
3.
Scroll through the parameters by repeatedly pressing the
push-button (60) until you reach the "BATTERY TYPE"
parameter
4.
If necessary, change the setting using push-buttons (58)
and (59).
Battery Removal
1.
Engage the parking brake.
2.
Remove the ignition key (51).
3.
Open the battery compartment hood (19) and fasten it with the support rod (47).
4.
Disconnect the battery connector (45).
5.
Disconnect the battery wiring harness (42).
6.
Remove any square guide or bracket fastening the batteries.
7.
Check that WET battery caps (43) are closed, to prevent the highly corrosive acid from leaking out of the batteries.
8.
With the help of an appropriate hoisting system, remove the batteries (42).
20
INSTRUCTIONS FOR USE
SW5500, FLOORTEC R 985 - 1466465000
BATTERY
PLUG
6V
6V
6V
6V
BATTERY
PLUG
24V
Figure 2