When the overheating safeguard switches the heater off, set the mode selector dial to 'OFF'
(off), unplug and allow the heater to cool down. Remove and/or amend the cause of
overheating and reuse the heater as normal. If you cannot find a cause and overheating
recurs, stop using the heater, and take it in for inspection/repair.

Cleaning and Maintenance

Keep the heater clean. Deposits of dust and dirt in the appliance are a common cause of
overheating so these should be removed regularly. Switch off the heater, remove the plug
from the socket and allow the heater to cool down before cleaning or carrying out
maintenance work.
Wipe the outside of the heater regularly with a dry or slightly damp cloth. Do not use
aggressive soaps, sprays, cleaners or abrasives, waxes, polishes or chemical solutions!
Use a vacuum cleaner to carefully remove any dust and dirt from the grills and ensure
that the air intake and outlet openings are clean. Be careful not to touch or damage any
internal parts during cleaning!
The heater contains no other parts which need maintenance.
At the end of the season, store the cleaned heater in the original packaging if possible.
Store it upright in a cool, dry and dust-free place.
Do not dispose of heater with household waste when it becomes worn or damaged
beyond repair. Take it to your local authority's collection point for electrical appliances
where any reusable materials will be collected and redistributed.

CE-statement

Euromac bv, Genemuiden-NL hereby declares that the EUROM electrical convector
heater, type MICA-HEAT-WAVE 1600, complies with the LVD guideline 2006/95/EG and the
EMC guideline 2004/108/EC and meets the following standards:
EN 60335-1:2012+A11 :2014
EN 60335-2-30:2009+A11:2012
EN 62233:2008
Genemuiden, 23-06-2015
W.J. Bakker, alg.dir.
----------------------------------------------------------------------------------------------------------------------------
Données techniques
Type
Tension
Puissance max.
Possibilités de réglage
Dimensions
Poids
EN 55014-1:2006+A1:2009+A2:2011
EN 55014-2 :1997+A1:2001+A2:2008
EN 61000-3-2 :2006+A1:2009+A2:2009
EN 61000-3-3 :2013
Français
EUROM MICA-HEAT-WAVE 1600
220-240 Volts / 50 Hz
1 600 Watts
600 – 1 000 – 1 600 Watts
16 x 67 x 50 cm
4,4 kg
17