Wacker Neuson HI400HD D Notice D'emploi page 60

Masquer les pouces Voir aussi pour HI400HD D:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Setting up the Burner
(See topic Checking/Adjusting the Gas Pressure.)
8. Conduct a smoke spot test. Follow the smoke spot tester manufacturer's
instructions and the general guidelines below.
■ Use the access hole in the exhaust stack.
■ Several samples should be taken as the heater warms.
■ The final sample should be taken just before the heater reaches 71°C (160°F).
9. Analyze the combustion. Follow the combustion analyzer manufacturer's
instructions and the general guidelines below.
■ Use the access hole in the exhaust stack.
■ Take several samples as the heater warms.
■ Take the final sample just before the heater reaches 71°C (160°F).
10.Re-adjust the air band, if necessary, until the smoke spot test and combustion
analysis are within the following parameters:
■ O
2
■ Smoke spot: less than 1
Result
The burner has now been set.
5/16 in. dia.
(8 mm)
18 in. (450 mm)
HI Heater
content: 3–5%
ghi_gr007395
60
HI400HD D / HD G
ghi_tx001464gb_FM10.fm

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Hi400hd g