4 . Units:
4
Class IIa medical device in accordance with Directive 93/42/CEE.
Software version . . . . .. ....... ....... ....... ........ ....... ....... ....... ...... 1
Type of current . . . . . . . ....... ....... ..... ....... ....... ....... ....... ........ .. Symmetrical biphasic rectangular
Number of programs .. ....... ....... ....... ........ ....... ....... ....... ..... 8 programs
Number of adjustable independent channels . ....... ....... ....... .... 2
Current . . . . . . . . . . . . . . . . .... ....... ............ ....... ....... ....... ........ ...... From 0 to 70 mA - from 0 to 60 Vcc - from 0 to 1000 Ω
Frequency range/Pulse width range .. ....... ....... ....... ....... ........ From 1 to 100 Hz/From 160 to 320 μs
Power. . . . . . . . . . . . . . . . . . . ..... ....... ....... ....... ........ ....... ....... ....... .. Rechargeable LiPo battery. 3.7V - 420mAh
Unit dimensions and weight ....... ........ ....... ....... ....... ....... .... 78x52x20 mm - 51 g
Automatic stop at the end of each program .... ....... ....... ....... ... Yes - after approx. 4 min 30 sec of inactivity
Activation safety. . . . . ... ....... ....... ..... ....... ....... ....... ........ ....... 100%
Detection absence of contact .... ....... ....... ....... ........ ....... ...... Yes - independent detection on each of the 2 outputs
Indicator of power . . .. ....... ....... ........ ....... ....... ....... ....... ...... LCD display: 2 bar graphs
Indicator of low and/or defective battery ...... ....... ........ ....... .... Yes - LCD display
Indicator absence of belt contact ... ....... ....... ........ ....... ....... .. Yes - LCD display
Indicator of programs ...... ....... ....... ....... ....... ........ ....... ....... LCD display: icons 1-2-3-4-5-6-7-8
Temperature/Relative humidity for storage . ....... ....... ........ ...... 0°C to + 45°C/10% to 90%
Temperature/Relative humidity for use .... ....... ....... ....... ....... ... + 5°C to + 45°C/20% to 65%
Connection of the electrodes .. ....... ....... ....... ....... ....... ........ . 2 snap fasteners per electrode
Warning . . . . . . . . . . . . . . . . ........ ....... .... ........ ....... ....... ....... ....... .. Read the instructions carefully
Conformity . . . . . . . . . . . . ..... ........ ....... ....... ....... ....... ....... ........ . EN60601-1/EN60601-2-10
Guarantee/Life cycle ..... ....... ............ ....... ....... ........ ....... .... 2 years
Type BF . . . . . . . . . . . . . . . . ... ....... ....... ........ ....... ....... ....... ....... ..... Device in contact with the patient, excluding the heart area.
RoHS (2002/95/EC) . ..... ....... ....... ....... ....... ........ ....... ....... ... The device is free of materials likely to have a negative impact on
IP22 . . . . . . . . . . . . . . . . . . . . . ..... ....... ............ ....... ....... ........ ....... .... Protected against foreign bodies ≥ 12.5 mm and vertically dripping
IX. RECYCLING
Please respect national regulations when you dispose of your product when it reaches the end of its life.
Please take it to a suitable place in order to ensure that it is disposed of in a safe and environmentally-friendly manner.
X. GUARANTEE
We provide a 24 month guarantee for products supplied by us, from the date of purchase.
f
f
The belt and adhesive electrodes are for personal use.
f
f
For hygiene reasons, they can therefore neither be returned nor exchanged.
The life expectancy of the adhesive electrodes is estimated at approximately 40 uses.
Never attempt to repair or modify the device yourself, or by a repairman not authorized by GlobalStim.
f
f
The guarantee becomes null and void if repairs have been carried out by non-authorized persons or if the replacement parts
used are not from the same manufacturer.
Similarly, only use GlobalStim-compatible accessories manufactured by SPORT-ELEC®.
f
f
During the guarantee period we repair, free of charge, manufacturing defects or faulty parts, reserving the right to decide if
f
f
certain parts need repairing or replacing, or if the device itself must be replaced.
Any damage resulting from improper use (knocks, plugging into a direct current, wrong voltage, ...) does not fall under the
f
f
guarantee; normal wear and tear does not affect the proper functioning or value of the device.
The guarantee is only valid if the date of purchase and the stamp and signature of the retailer appear on the guarantee certifi-
f
f
cate, or upon presentation of the till receipt. (See «guarantee certificate» at the end of this manual
No other claims fall under the guarantee, unless otherwise provided by law.
f
f
16
- USER MANUAL
the environment.
water when tilted at an angle of up to 15°