Care & Maintenance - Elcometer 2020 Guide D'utilisation

Finesse de broyage
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 27
3 TEST PROCEDURE (continued)
3.3 CLEANING AFTER TEST
Always clean the gauge after each test using a suitable solvent. After
cleaning and to protect against rust , ensure that all materials are
removed and that the gauge is dry. Apply a thin layer of oil to the
surface of the gauge and the scraper before storage.
DO NOT use very aggressive solvents or wire brushes, metal
scrapers, metal files, or other metallic tools for cleaning.
Store the gauge and scraper in the case provide when not in use.
4 CARE & MAINTENANCE
Regularly inspect the gauge and scraper for signs of wear or damage.
To inspect the scraper:
1
Place the edge of the scraper on a
reference plane (the smooth, level face of
the gauge is a good alternative).
2
Shine a bright light towards the back of the
scraper. Rock the scraper backwards and
forwards and inspect the contact edge for
any light coming through between the
scraper and gauge.
If light is visible, the scraper is not suitable for use and should be
replaced.
Description
Replacement Scraper for Elcometer 2020
Replacement Scraper for Elcometer 2050
Replacement Scraper for Elcometer 2070
c
Rust can appear on the gauge when it is only used occasionally and when it has been handled by users
with sweaty hands.
www.elcometer.com
c
Part Number
KT002020N001
KT002030N001
KT002070N001
R
en-4

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

20502070

Table des Matières