Installation
1.
Ancor the pump to the concrete pad.
2. Remove the pump covers and assemble the
protection screen skirt if this is required (A).
3. Connect the ducting to both the inlet and the
outlet. Do not start the pump without having it
connected to the ductwork.
4. The pump inlet should always be connected
to a separator with a fi lter unit (B). The pump
cannot tolerate contaminated airfl ow .
5. Extra silencing can be installed if the outlet
sound level is to be lowered from approxima-
tely 75 dB(A) to approximately 62-64 dB(A).

Test Running

1.
Verify that the power is locked out. Inspect the
belt tension (Figure B next page), rotate the
pump and listen for any sound indicating worn
bearings or misaligned impellers. Check that
the inlet and outlet are properly connected.
Also check that the vacuum relief valve is con-
nected.
2. Mount the covering panels. Check that no per-
sons can be hurt if the pump starts and that all
outlets are closed.
3. Connect a manometer for negative pressure
calibrated to min. -50 kPa to the suction side
as close to the pump as possible.
4. Power up the pump and listen carefully for the
following sounds; A high pitch whine is nor-
2018-06-08
6. If the outlet is vertical, and exposed to the ele-
ments, rain protection should be installed (C).
Exhaust air can be very hot, up to 150
7.
Electrical connections may only be performed
by a certifi ed electrician. A separate locka-
ble disconnect should be installed where it
is readily accessible and within view of the
pump.
8. Thermal overload protection must be installed
to validate the warranty.
9. The control panel must be equipped with an
over-load protection that should be adjusted
and tested by a certifi ed electrician. Check for
correct motor rotation.
mal sound from the impeller blades. As pump
draws cooling air from the vacuum relief valve
a weak hissing should be heard.
5. Measure the pressure. Compare with the di-
mension point. The pressure can be adjusted
by adjustment of the vacuum relief valve. See
- Adjusting the vacuum relief valve.
6. Check the function and tightness of the con-
nected exhaust system.
7.
Open the number of outlets the system is di-
mensioned for. The vacuum relief valve should
now be totally closed.
8. It is normal that the pump becomes hot during
operation.
TPR 35, 11 kW - 15
O
C.
Part No 9063-A