is clogged, the condensation water cannot drain completely out of the heat pump and
substantial quantities can collect there.
Pool water
Escaping pool water indicates that:
the hose is not connected correctly to the adapter
the adapter
the seal in the adapter
the pipe of the circuit inside the heat pump is leaking.
Refrigerant
Escaping refrigerant indicates that the refrigerant circuit in the finned heat exchanger has a leak.
Contact a qualified specialist promptly if you find a leak in the refrigerant circuit.
Please bear in mind that refrigerants have no odour.

Storage

Once the outdoor temperature falls below 10 °C on a continuous basis, the heat pump should be
put into winter storage to avoid damage due to the formation of ice (bursting due to freezing).

Winter storage

1. Disconnect all supply lines (see the chapter on "Deinstallation").
2. Cover the heat pump so it can breathe but is protected from coarse contamination and strong
weather influences.
The heat pump is now stored for the winter.
44
2
is not screwed onto the heat pump
2
is defective or missing.
2
.
1
correctly.