NOTE!
Risk of damage due to blockage of the air current!
Reduced or blocked ventilation of the heat pump can lead to insufficient
removal of heat or moisture. This can cause mould to form or overheating of
the finned heat exchanger.
- Clean the grille in front of the fan blade and the fins of the heat exchanger
regularly and ensure that debris such as leaves or the like do not enter the
inner part of the heat exchanger.
- Ensure that the grille on the heat exchanger is never covered over and air
can flow freely through the device.

RCD adapter

The RCD adapter
C
contact plug must be connected to a suitable power socket with a protective earth conductor. The
residual current device disconnects the heat pump from the electricity as soon as any unexpected
currents which are hazardous for humans flow via the heat pump (e.g. body contact via
electrically conductive parts of the housing).
Testing the residual current device
1. Connect the RCD adapter
site.
2. Press the RESET button 12.
The LED
lights up. The heat pump is supplied with electricity and is in the Standby mode.
11
3. Press the TEST button 13.
The LED
lights up. The heat pump is disconnected from the electricity and the Display
11
goes out.
4. Press the RESET button 12.
The LED
lights up. The heat pump is supplied with electricity and is in the Standby mode.
11
The residual current device of the RCD adapter has now been tested successfully.

Activating the heater

The temperature range that can be set in operating mode is 15-35°C. The standard value of the
set water temperature is 27°C.
You can heat the water in the pool fastest with maximum water flow through the heat
pump (see section "Technical data"). However, increasing the throughput reduces the
dwell time at the heat exchanger. As a result, the total temperature difference between
the water in the pool and the heated water at the inlet of the pool is smaller and
therefore less perceptible. Please measure and write down the change to the current
water temperature every 30 minutes to detect the actual heating of the pool water.
Activating operating mode
1. Press the
RESET12
The LED
is lit. The heat pump is being supplied with power and is in standby mode.
11
2. Press the
ON/OFF15
The heat pump
1
in °C.
40
consists of an earth-contact plug and a residual current device. The earth-
C
to the electrical supply that has been prepared at the installation
button.
button.
is in operating mode and the display
shows the current water temperature
14
14