Maintenance • Troubleshooting
Maintenance
Risk of electric shock . Can shock, burn or
kill. Disconnect the power before servicing, repairing, or
working on pump.
The pump's motor is completely sealed in the motor
housing and does not require any service. Disassembly
of the motor housing or modification or removal of
the power cord voids the warranty. The power cord is
not replaceable.
Troubleshooting
Risk of electric shock . Can shock, burn or kill. Unplug the pump before attempting to clean or work on
the pump.
NOTICE This pump has no serviceable parts inside the case. Opening the case will ruin the pump. If obstructions or
blockages of the impeller cannot be cleaned out from the outside (for instance, by washing out with a garden hose),
replace the pump.
Symptom
Possible Cause(s)
Blown fuse or tripped breaker.
Low line voltage
Pump won't start or run.
Defective motor.
Impeller
Low line voltage.
Something caught in impeller.
Pump operates but delivers
little or no water.
Worn or defective parts or plugged impeller.
Check valve installed without vent hole.
Intermittent running or pump
Thermal overload tripped
stopped automatically.
For parts or assistance, call Flotec Customer Service at 1-800-365-6832.
Never run the pump dry! Running the pump dry can
damage the seal, causing leakage. This pump is a
submersible type and must be in water at all times for
proper operation and cooling.
Periodically clean the suction screen. Make sure that
impeller rotation is not being hampered by any debris.
Thank you for purchasing
Flotec Products.
Corrective Action
If blown, replace with fuse of proper size.
If tripped, reset breaker.
If voltage under recommended minimum, check size of wiring from main switch
on property. If OK, contact power company or hydro authority.
Replace pump.
If impeller won't turn, locate source of binding and clean out with hose or
remove obstruction. Do not open case.
If voltage under recommended minimum, check size of wiring from main switch
on property. If OK, contact power company or hydro authority.
Clean out impeller or replace pump.
Clean impeller if plugged; otherwise replace pump.
Drill a 1/16" - 1/8" (1.6mm - 3.2mm) dia. hole between pump discharge and
check valve.
Protect the installation from the sun.
Pump cooler water.
Check for clogged impeller; clean if necessary from outside of case.
Pump has run dry; add water