Installation
Description
These submersible pumps are designed for use in
waterfall/ fountain applications or as a utility pump.
The units are equipped with a 3-prong grounding-type
power cord. Ball bearings on motor shafts never need
lubrication. Automatic reset thermal protection.
Pump water only with this pump.
Specifications
Power supply required. . . . . . . . . . . . . . . . . . . . . . . . 115V, 60 HZ.
Motor duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . continuous
Liquid Temp. Range. . . . . . . . . . . . . . . . . . 32°F to 100°F (0°-38°C)
Individual Branch Circuit Requirement (minimum) . . . . . . 15 Amps
Discharge Fittings: . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Figure 2
NOTICE Not designed for applications involving
salt water or brine! Use with salt water or brine will
void warranty.
Electrical Specifications
Motor
Motor Full
Model
H .P .
Load Amps
FP0S1200X
1/6
1.5
FP0S2300X
3/10
2.6
FP0S3000X
4/10
3.0
FP0S4100X
1/2
7.2
Installation
See Figure 1 for typical installation connections to pump
(NOTICE Fountain accessories not included with pump).
1. Install the pump on a hard level surface. Make sure
that the pump cannot pick up rocks, mud and debris,
etc. If neccesary, put a block under the pump to raise
it slightly. If used with a fountain jet, position the
pump so that the fountain jet is above the surface of
the water.
Performance
Model
Motor HP
FP0S1200X
1/6
1,200 (4,542)
FP0S2300X
3/10
2,300 (8,858)
FP0S3000X
4/10
3,000 (11,356)
FP0S4100X
1/2
4,100 (15,520)
For parts or assistance, call Flotec Customer Service at 1-800-365-6832.
Minimum Circuit
Pumps Down
Req . (Amps)
To
7/16" (11mm)
15
1-3/8" (35mm)
1 ( .3)
5 (1 .5)
1,000 (3,785)
675 (2,555)
1,975 (7,476)
1,425 (5,394)
2,500 (9,464)
1,900 (7,192)
3,600 (13,627)
3,000 (11,356)
GFCI
outlet
Power
cord
Landscaping rocks
Figure 1: Typical Garden Pond and Waterfall Installation.
2. Protect the power cord from damage. Uncovered
cords should be routinely inspected for damage or
deterioration. DO NOT operate the pump if the cord
is damaged.
3. If used in a garden pond, adjust the diverter valve
to control the fountain spray height and flow over
the waterfall. Do not restrict pump suction to adjust
flows. Restrictng the suction will starve the pump for
water and can damage the pump.
4. If the pump is connected to a pond filter, adjust the
diverter valve to provide adequate flow to the filter.
Refer to the filter instruction manual to determine
flow requirements of filter.
GPH (LPH) At Total Feet (M)
10 (3)
15 (4 .6)
400 (1,514)
850 (3,218)
1,320 (4,997)
2,400 (9,085)
Use foliage to cover
tubing to waterfall
Diverter valve
Raise the pump off the
bottom of the pond
20 (6 .1)
25 (7 .6)
300 (1,136)
750 (2,839)
1,650 (6,246)
900 (3,407)
4
Plastic
tubing to
waterfall
No Flow At Height
Shown Below
20' (6.1 M)
22' (6.7 M)
25' (7.6 M)
30' (9.1 M)