Signal strength (SENS)
The maximum detection range is 12m frontally with wall
mounting, and can be set in steps between
20% and 100%.
Ceiling mounting
max. 8 m
Wall mounting
Light value (LUX)
The system is equipped with a daylight sensor for additional
energy savings that prevents the lighting being switched on,
despite movement and with sufficient daylight.
The setting range of the light value is implemented in steps
between 5 lux and daylight operation.
14
360°
max. 8 m
Overview of possible parameter settings
Programming of individual parameters is specified in the ope-
rating instructions of the infrared remote control included with
this unit.
Parameter
SENS
Signal strenght
1
20%
2
40%
3
60%
4
80%
5
100%
Factory
80%
setting
*Learn mode:
Learn mode enables measuring the ambient light for optimal setting
of the threshold value to real conditions.
TIME
LUX
Hold time
Light value
Daylight
1 min.
300 lux
5 min.
30-50 lux
10 min.
5-10 lux
15 min.
Learn mode*
30 min.
Daylight
5 min.