Overview of possible parameter settings
Programming of individual parameters is specified in the ope-
rating instructions of the infrared remote control included with
this unit.
Parameters
SENS
Signal strenght
1
20%
2
40%
3
60%
4
80%
5
100%
Factory
80%
setting
*Learn mode:
Learn mode enables measuring the ambient light for optimal setting
of the threshold value to real conditions.
Electrical connection
• Electrical connection must only be carried out by professio
nal personnel trained and authorised for this purpose.
DALI sensor luminaire without through-wiring
Single luminaire (...ETDD+HFS)
N
L
18
TIME
LUX
DIM
Hold time
Light value
Dimmniveau
Daylight
1 min.
0%
300 lux
5 min.
10%
30-50 lux
10 min.
10%
5-10 lux
15 min.
30%
Learn mode*
30 min.
50%
Daylight
5 min.
0%
...ETDD + HFS
DALI sensor luminaire with through-wiring
Master-slave connection (...ETDD+LV+HFS)
The DALI sensor luminaire enables control of up to 14 further
DALI luminaires. For this, all further luminaires (slaves) are
merely connected via the DALI bus with the sensor luminaire
(master).
N
L
...ETDD + LV
...ETDD
DALI sensor expansion luminaire with through-wiring
Master-master connection (...ETDD+LV+HFM)
For expanding the detection range, several sensor luminaires
can be interconnected via the DALI bus.
Observe here that with a master-master combination the DALI
inputs and outputs of the expansion luminaires (...+HFM) must
not be interconnected.
N
L
...ETDD + LV
...ETDD
...ETDD + LV + HFS
DA/OUT
DA/OUT
DA/OUT
DA/OUT
...ETDD + LV
...ETDD + LV + HFS
DA/OUT
DA/OUT
DA/OUT
DA/OUT
...ETDD + LV + HFM
DA/OUT
DA/IN
DA/OUT
DA/IN
19