For a plug connection, insert the safety plug of the mains ca-
ble 23 into a safety socket near to the access point.
 Do not use an extension cable!
If you connect the access point directly to the power mains
(fixed connection), you require an additional switching ele-
ment in order to disconnect the access point from the current
if required (e.g. assembly or maintenance work). This on/off
switch should be accommodated in a readily accessible posi-
tion in the vicinity of the access point.
Connecting the Access Point to the PC
(see figure D)
You can connect the EXAConnecT access point both directly
to your PC and to a company-specific network. You require
network cables with an RJ45 plug to do this.
– Remove the maintenance cover plate 8 (see "Connection
Work", page 27).
– Loosen the locknut 12 on the left-hand cable gland 11 by
turning it counterclockwise.
– Pull the plugless end of the network cable 25 through the
opening in the cable gland 12 to the terminal strip 18.
– Measure at the 8-pin plug which colour is at which pin.
Refer to the table (see "Pin assignment of the Ethernet in-
terface", page 28) to see which wires you need for the con-
nection to the access point, and insulate the wires that are
not needed.
– Connect the remaining wires to the "100MB" network con-
nection of the terminal strip 18 in accordance with the ta-
ble.
– Connect the shield of the patch cable to the ground termi-
nal 13.
Use the crossover assignment to directly connect the access
point to your PC and the 1:1 connection to connect to your
company network, server or network hub.
– Check whether the cable is securely fitted. Then retighten
the locknut 12 on the cable gland 11 by turning it clock-
wise.
Pin assignment of the Ethernet interface
Pin
Colour of the
Crossover
wires, e.g.
assignment
1
white/orange
RD+
2
orange
RD-
3
white/green
TD+
4
blue
5
white/blue
6
green
TD-
7
white/brown
8
brown
Network Connection of the Access Point
During installation you have to set the network parameters
for the connection of the access point to your computer.
– Insert the plug of the cable 25 into the network connection
port of your PC if you have chosen crossover assignment
on the access point for the Ethernet connection.
3 609 929 C48 | (30.10.13)
For a 1:1 connection, insert the plug into a free network
socket of your company network.
– Connect the access point to the power supply (see "Con-
necting the Access Point to the Power Supply", page 27).
– Set the network parameters (see "Setting the Network Pa-
rameters", page 28).
After a short time, the yellow LED indicator 4 flashes and en-
circling bars appear on the display 6. After a few seconds, the
green LED indicator 3 shows by way of a continuous light that
the access point is ready for operation.
Setting the Network Parameters
The access point is delivered with the IP address
10.10.10.10. This IP address should no longer be used in
your network.
Crossover assignment (access point and stand alone PC)
For the exchange of data between your PC and the access
point, your PC must be set to a static IP address.
– Open the properties dialogue field for network connec-
tions in your operating system.
– Select the internet protocol (TCP/IP) that is linked to the
network connection to which you have connected the ac-
cess point.
– Click on Properties.
– Activate the Use the following IP address option.
– Enter the following settings into the fields for the static IP
address:
IP address: 10.10.10.5
Subnet mask: 255.255.255.0
In some cases, it may be necessary to route the access point.
– Start the Command Prompt window.
– Enter the command
route add 10.10.10.10 10.10.10.5
and press Enter.
– Open the web browser on your PC and enter the following
address:
http://10.10.10.10
After a short time, a security certificate will open and you
should confirm it in order to have available all functions of the
1:1 connection
access point.
on network
The Java applet is loaded. You now have access to the
TD+
EXAConnecT access point.
TD-
Access point and network
RD+
– Open a web browser and enter http://10.10.10.10 in the
address bar.
▷ The software is loaded.
– Select the EXAConnecT tab.
RD-
– Click on the Setup button.
▷ The EXAConnecT Setup window is displayed.
– Select the TCP/IP Settings tab.
▷ The Get network parameters automatically (DHCP)
option is not selected.
– Enter a free IP address in the desired address range into
the IP Address input field.
The standard value 255.255.255.0 normally does not
have to be changed. If required, enter the IP address of the
gateway into the Default Gateway input field.