2
TEMPERATURE DISPLAY
If you notice a difference of reading between temperature shown by the device, you can adjust this value:
Access the control menu : press 3 s on
Select the code « t° » using
Adjust the desired value using
SECURITIES
3
The device is protected by several securities:
Securities
A1
The device has detected a salt rate < 2,5 kg/m
The chlorine PRODUCTION is interrupted.
Add salt to obtain 5 kg/m
A2
The device detected a lack of water in the chlorinator cell
The chlorine PRODUCTION is interrupted.
Verify that the hydraulic system of the filtration allows the passage of water in the cell (in
particular the water gates position).
The device detected a default of chlorine production.
The chlorine PRODUCTION is not interrupted.
1/ No water : Check the entire hydraulic circuit of the pump timer and the water level in the
A3
pool (in particular the water gates position).
2/ Check the connexions in the borders of chlorinator cell.
If one or both of the connexions are oxidized or deteriorated, please send the cell and its cable
to your professional for an expertise.
3/ Remove the cell and check it's not scaled (If so proceed as described § 6.4, p.39). If none of
these elements resolves the problem, contact your professional.
A4
The device detected a lack of flow in the chlorinator cell.
The chlorine PRODUCTION is interrupted.
Check the entire hydraulic circuit of the pump timer and the water level in the pool (in
particular the water gates position).
Water temperature decreases bellow 15°C. To protect chlorinator cell, the device has to stop
Hi
the chlorine production and it appears "Hi" on display.
This alarm will turn off automatically when water temperature exceeds 15°C.
JUSTSALT UNO - JUSTSALT DUO - JUSTSALT PRO - PAPI004084MULTI1 - FR/EN/ES/IT - Rev.01.16
V
.
and then confirm by
then confirm by
Causes / Remedies
3
.
3
(see tab § 4.2, p.32), the device will automatically restart.
.
V
.
V
20