For Duo Model - pH regulation menu
Code
Start a manual injection of the pH pump.
MA
When installing, allows starting the pH pump and allows correcting manually the pH.
Calibrate the pH probe.
Ad
Allows by the device to display the pH value found in your swimming pool with your
analysis kit.
Choose the type of corrective agent (by default : acid).
Co
Allows modifying the pH corrective mode between acid (make rise the pH up) or
basic (make fall down the pH).
Adjust the volume of the pool.
CP
This device has a proportional regulation to the volume of the pool. For an optimal
efficiency, register in the device, the code corresponding to the volume of the pool :
Pool volume
0 to 1 m
1 to 2 m
2 to 3 m
3 to 4 m
4 to 5 m
5 to 6 m
6 to 7 m
7 to 8 m
8 to 9 m
9 to 10 m
Adjust the pH instruction (7,2 by default).
SE
Allows adjusting the pH value to maintain in the swimming pool.
Maintenance / Diagnostic of the failures parameters :
Calibrate the pH probe with the pH 7 and pH 10 solutions (see § 6.2, p.37)
CA
For Pro Model - Redox regulation menu
Code
rE
Ma
pH
rE
Ad
pH
Co
rE
SE
pH
Maintenance / Diagnostic of failures parameters :
Calibrate the redox probe : maxi distance : +/- 100 mV (see § 6.3, p.38).
CA
JUSTSALT UNO - JUSTSALT DUO - JUSTSALT PRO - PAPI004084MULTI1 - FR/EN/ES/IT - Rev.01.16
Code
Pool volume
3
01
10 to 15 m
3
02
15 to 20 m
3
03
20 to 25 m
3
04
25 to 30 m
3
05
30 to 35 m
3
06
35 to 40 m
3
07
40 to 45 m
3
08
45 to 50 m
3
09
50 to 55 m
3
10
55 to 60 m
Forced march of the salt chlorinator
Allows forcing the salt chlorinator supply and its production for a while
fixed.
Start a manual injection of the pH pump
Allows correcting by hand the pH without manipulating the tin or priming
the pH pump by example.
Calibrate the Redox probe (by step of 10 mV)
Allows making show by the device the redox regulation found in your pool
with your analysis kit.
Calibrate the pH probe
Allows making show by the device the pH value found in your pool with
your analysis kit.
Choose the type of corrective agent (by default : acid).
Allows modifying the pH corrective mode between acid or basic.
Adjust the redox regulation instruction (by step of 10 mV)
Allows adjusting the redox regulation instruction (by default : 670 mV).
Adjust the pH instruction (7,2 by default).
Allows adjusting the pH value to maintain in the pool.
Function
Code
Pool volume
3
11
60 to 70 m
3
12
70 to80 m
3
13
80 to 90 m
3
14
90 to 100m
3
15
100 to 110m
3
16
110 to 120 m
3
17
120 to 130 m
3
18
130 to 140 m
3
19
140 to 150 m
3
20
150 to 160 m
Function
From 0 to 9,5
+/- 0,5 compared
to the displayed
Acid (pH-)
Basic (pH+)
Code
3
21
3
22
3
23
From 5 to 160 m
3
24
3
25
3
26
3
27
3
28
3
29
3
30
From 6.8 to 7.6
Setting
From 1 h to 24 h
From 0 to 990 ml
From 400 to 800 mV
+/- compared with
the shown value
Acid (pH-)
Basic (pH+)
From 550 to 750 mV
From 6.8 to 7.6
12
Setting
value
3