4 OPERATION
4.3 Specific Fitting Factors classified according to DN and Material Type 1500/01
DN
mm
15
20
25
32
1 1/4
40
1 1/2
50
65
2 1/2
80
100
DN
15
20
25
32
1 1/4
40
1 1/2
50
65
2 1/2
80
100
Fig. 4 K-Factors classified according to DN and Material - Fitting type 1500/1501
The K-factor (specific fitting factor) has been measured on a certified calibration rig
with water at 20°C and with a flow velocity of 2 m/s.
This K-factor depends upon the installation conditions.
Repeatability is better than ±0.4%.
with Bürkert standard fitting with specific sizes (See data sheet 8025, 1500, 1501).
with Bürkert weld-in taps and saddle-fittings under reference conditions (fluid and
pipe sizes). In case of deviation from these reference conditions, the mentioned K-factor
can change. Please ask for advise to Bürkert salesmen.
Note: Conversion to Imperial Gallons: K[pulse/Impgal] = 4,55 x K [pulse/l]
Inch
Metal
1/2
117,6
3/4
68,8
1
42,7
25,4
17,73
2
11,46
7,01
3
5,04
4
2,85
Specific Fitting Factor K [pulse/USgal]
1/2
445,2
3/4
260,4
1
161,6
96,1
67,11
2
43,38
26,54
3
19,08
4
10,79
PULSE DIVIDER TYPE 8021
Specific Fitting Factor K [pulse/l]
PVC
139,8
74,4
46,6
28,6
17,61
10,18
7,30
4,56
2,83
529,2
281,6
176,4
108,3
66,66
38,54
27,63
17,26
10,71
-18-
PP
PVDF
155,1
131,6
88,1
79,1
50,6
49,2
34,8
31,1
19,60
17,30
12,00
9,76
7,43
6,75
4,64
4,48
2,88
2,80
559,90
587,1
349,17
333,5
191,5
186,2
131,7
117,7
74,19
65,49
45,42
36,95
28,13
25,55
17,56
16,96
10,90
10,60
8021