15. E
XCHANGING THE
The aerial feed cables supplied as standard are of adequate
length for most applications.
However, aerials with different feed cable lengths are also
available for special applications:
(# 89 3022): overall length 230 mm (standard)
(# 89 3020): overall length 400mm
See Chapter (
8.1) for details of aerial installation.
! When disconnecting a receiver aerial always pull on the
connector itself - never on the feed cable ("the wire")!
! Caution: if the active part of the aerial (the last 30 mm)
should suffer damage, the aerial must be replaced! The
same applies to damaged aerial feed cables.
16. E
LIMINATING OVERLOAD SITUATIONS AT
INDIVIDUAL SERVO SOCKETS
The RX-9/12/16-DR pro M-LINK receiver types are fitted as
standard with fuses which protect the individual servo sockets
(1, ..., 9/12/16) and the sensorports (S). The maximum load
tolerated by a fuse, and therefore by an individual servo channel
1, ..., 9/12/16 or sensorport S is a continuous 5.0 A; the peak
load for ten seconds is 7.5 A (depending on cooling and other
arrangements, ...).
! Caution: never connect a receiver battery or a BEC
system directly to a servo socket or sensorport!
If you were to do this, the full current of the receiving system
(including all connected servos, speed controllers, gyros, ...)
would flow through this ONE servo socket. This could overload
that servo socket, and cause the corresponding fuse to blow. If
the fuse were to burn out, the result would be failure of the
power supply to the receiving system, and an inevitable crash.
For this reason the receiver battery should only ever be
connected to the sockets marked B/D or BATT!
If you wish to connect a speed controller with integral BEC
system to one of the servo sockets 1, ..., 9/12/16, then the
positive wire should be withdrawn from the UNI connector,
and the bare end insulated. In this case a separate receiver
battery must be used to supply the receiving system; this
should be connected to the socket marked B/D or BATT.
Alternatively the signal wire can be connected to one of the
servo sockets 1, ..., 9/12/16. In this case the positive and
negative wires can be connected to B/D or BATT (observe
correct pin assignment!).
! Note: if a servo connected to a receiver socket suddenly
stops working, you can assume that the fuse for this one servo
socket has blown due to overloading. The servo connected to
this socket should be subjected to a careful check before it is
used again.
Send the receiver to MULTIPLEX or an authorised MULTIPLEX
Service Centre for replacement of the fuse.
17. CE C
ONFORMITY
This device has been assessed and approved in
accordance with European harmonised directives.
This means that you possess a product whose design and
construction fulfil the protective aims of the European Com-
munity designed to ensure the safe operation of equipment.
The detailed CE conformity declaration can be downloaded in
the form of a PDF file from the Internet under www.multiplex-
rc.de. It is located in the DOWNLOADS area under PRODUKT-
INFOS.
Operating Instructions for
RX-9/12/16-DR pro M-LINK 2.4 GHz receivers
A
ERIALS
D
ECLARATION
18. D
ISPOSAL
Electrical equipment marked with the cancelled waste
bin symbol must not be discarded in the standard
household waste; instead it should be taken to a
suitable specialist disposal system.
In the countries of the EU (European Union) electrical
equipment must not be discarded via the normal
domestic refuse system (WEEE - Waste of Electrical and
Electronic Equipment, Directive 2002/96/EG). You can take
unwanted equipment to your nearest local authority waste
collection point or recycling centre. There the equipment will be
disposed of correctly and at no cost to you.
By returning your unwanted equipment you can make an
important contribution to the protection of the environment!
19. G
UARANTEE
The company MULTIPLEX Modellsport GmbH & Co.KG accepts
no liability of any kind for loss, damage or costs which are due to
the incorrect use and operation of this product, or which are
connected with such operation in any way. Unless the law
expressly states otherwise, the liability on the part of MULTI-
PLEX Modellsport GmbH & Co.KG to pay damages, regardless
of the legal argument employed, is limited to the invoice value of
those products supplied by MULTIPLEX Modellsport GmbH &
Co.KG which were directly involved in the event in which the
damage occurred. This does not apply if liability is incurred
according to statutory law on account of intentional or gross
negligence.
We guarantee our products in accordance with the currently
valid statutory regulations. If you wish to make a claim under
guarantee, your initial course of action should always be to
contact the dealer from whom you purchased the equipment.
The guarantee does not cover faults and malfunctions which are
caused by the following:
Incorrect or incompetent use
Maintenance carried out incorrectly, belatedly or not at all, or
not carried out by an authorised Service Centre
Incorrect connections
The use of accessories other than genuine MULTIPLEX
items
Modifications or repairs which were not carried out by
MULTIPLEX or by an authorised MULTIPLEX Service
Centre
Accidental or intentional damage
Defects due to normal wear and tear
Operation of the unit outside the limits stated in the
Specification
Operation of the unit in conjunction with equipment made by
other manufacturers.
Page 17