Model Designation; Specifications; Refrigerated Well; Condensing Unit (Cwbr Models Only) - Hatco CWBR Série Manuel D'installation Et D'utilisation

Masquer les pouces Voir aussi pour CWBR Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English

Refrigerated Well

Model
CWBR-1 and CWBX-1
CWBR-2 and CWBX-2
CWBR-3 and CWBX-3
CWBR-4 and CWBX-4
CWBR-5 and CWBX-5
CWBR-6 and CWBX-6
* Recommended line size for installations of 50' or less.

Condensing Unit (CWBR Models only)

Model
Volts
120
CWBR-1
240
120
CWBR-2
240
120
CWBR-3
240
120
CWBR-4
240
120
CWBR-5
240
120
CWBR-6
240

Solenoid Valve (CWBX Models only)

Volts
Hertz
120
50/60
240
50/60
The shaded areas contain electrical information for International models only.
Form No. CWBRm-0416
C W B R - 1
Cold Well
Built-In
Line Size*
Suction
Liquid
BTU/Hour
3/8"
1/4"
3/8"
1/4"
3/8"
1/4"
3/8"
1/4"
1/2"
1/4"
1/2"
1/4"
Compressor Size
1/4 hp
1/4 hp
1/4 hp
1/4 hp
1/4 hp
1/4 hp
1/3 hp
1/3 hp
1/2 hp
1/2 hp
1/2 hp
1/2 hp
Watts
Amps
12
17
Full-Size Pan Capacity
R = w/Remote Condensing Unit
X = Well Only
Load
330
630
930
1230
1530
1830
Watts
Amps
High Side
804
6.7
383 psig
(26.41 bar)
804
3.4
804
6.7
383 psig
(26.41 bar)
804
3.4
804
6.7
383 psig
(26.41 bar)
804
3.4
1044
8.7
423 psig
(29.16 bar)
1044
4.4
1380
11.5
425 psig
(29.3 bar)
1380
5.8
1380
11.5
425 psig
(29.3 bar)
1380
5.8

Refrigerant Information

all Hatco CWBR and CWBX model Refrigerated Drop-In Wells
use R-404a refrigerant.
0.1
0.1
5

MODEL DESIGNATION

SPECIFICATIONS

Design Pressure
Low Side
244 psig
(16.82 bar)
244 psig
(16.82 bar)
244 psig
(16.82 bar)
244 psig
(16.82 bar)
244 psig
(16.82 bar)
244 psig
(16.82 bar)

Publicité

Chapitres

Table des Matières
loading

Table des Matières