English
Refrigerated Well
Model
CWBR-1 and CWBX-1
CWBR-2 and CWBX-2
CWBR-3 and CWBX-3
CWBR-4 and CWBX-4
CWBR-5 and CWBX-5
CWBR-6 and CWBX-6
* Recommended line size for installations of 50' or less.
Condensing Unit (CWBR Models only)
Model
Volts
120
CWBR-1
240
120
CWBR-2
240
120
CWBR-3
240
120
CWBR-4
240
120
CWBR-5
240
120
CWBR-6
240
Solenoid Valve (CWBX Models only)
Volts
Hertz
120
50/60
240
50/60
The shaded areas contain electrical information for International models only.
Form No. CWBRm-0416
C W B R - 1
Cold Well
Built-In
Line Size*
Suction
Liquid
BTU/Hour
3/8"
1/4"
3/8"
1/4"
3/8"
1/4"
3/8"
1/4"
1/2"
1/4"
1/2"
1/4"
Compressor Size
1/4 hp
1/4 hp
1/4 hp
1/4 hp
1/4 hp
1/4 hp
1/3 hp
1/3 hp
1/2 hp
1/2 hp
1/2 hp
1/2 hp
Watts
Amps
12
17
Full-Size Pan Capacity
R = w/Remote Condensing Unit
X = Well Only
Load
330
630
930
1230
1530
1830
Watts
Amps
High Side
804
6.7
383 psig
(26.41 bar)
804
3.4
804
6.7
383 psig
(26.41 bar)
804
3.4
804
6.7
383 psig
(26.41 bar)
804
3.4
1044
8.7
423 psig
(29.16 bar)
1044
4.4
1380
11.5
425 psig
(29.3 bar)
1380
5.8
1380
11.5
425 psig
(29.3 bar)
1380
5.8
Refrigerant Information
all Hatco CWBR and CWBX model Refrigerated Drop-In Wells
use R-404a refrigerant.
0.1
0.1
5
MODEL DESIGNATION
SPECIFICATIONS
Design Pressure
Low Side
244 psig
(16.82 bar)
244 psig
(16.82 bar)
244 psig
(16.82 bar)
244 psig
(16.82 bar)
244 psig
(16.82 bar)
244 psig
(16.82 bar)