5.2. Compressed air preparation and port
Motor and compressed air cylinder are lubricated by the oil vapour of the compressed
air. Faultlessly prepared compressed air is therefore a prerequisite for a problem-free
operation of the unit. This can only be met by a properly working 3/8" maintenance unit
comprising water separator, pressure reducing valve incl. pressure gauge and oiler.
The oiler is to discharge sufficient oil, i.e. approx. 1 drop per strapping operation.
The length of the hose should not exceed 5 m. The inside diameter of the hose is
minimum 8 mm. Attention should be paid, that the hose is without loops in which oil
could gather.
Choice of the lubricating oil: resin- and acid-free lubricating oil with a viscosity of
2-4° E at 50°.
MAX-L
In no case it is allowed to run the tool without oil being in the
lubricator of the maintenance unit, as this would immediately
destroy the compressed air motor. No warranty in that case.
min. operating pressure 6 bar (flow pressure)
max. operating pressure 7 bar (back pressure)
Attention! Risk of tearing band! The band can get torn when
the operating pressure of 7 bar is exceeded. Tearing band
can result in injuries of the operating staff.
H 264 EU 45/16
26 / 53