VACUUM SYSTEM MOTOR FILTER CLEANING
1.
Drive the machine on a level fl oor.
2.
Disconnect the power supply cable (3) from the electrical mains.
3.
Remove the recovery water tank retaining plate (36).
4.
Open the recovery water tank.
5.
If necessary, drain the water from the tank in order to make the fi lter visible.
6.
Check that the pre-fi lter is clean. If necessary clean it with water and compressed air, then install it.
7.
Perform steps 1, 2, 3 and 4 in the reverse order.
SOLUTION/CLEAN WATER FILTER CLEANING
1.
Drive the machine on a level fl oor.
2.
Disconnect the power supply cable (3) from the electrical mains.
3.
Close the solution tap (A, Fig. 5) under the machine, behind the right rear wheel. The tap (A) is closed when it is in the position
(B) and it is open when it is in the position (C).
4.
Remove the transparent cover (D), then remove the fi lter strainer (E). Clean and install them on the support (F).
NOTE
The fi lter strainer (E) must be correctly positioned on the housing (G) of the support (F).
5.
Open the tap (A).
G
E
9097056000(1)2007-02 A
F
E
D
USER MANUAL
Figure 5
SCRUBTEC 545E – 553E
ENGLISH
A
B
C
P100109
17