H
Appliances
A
B
Single oven
56
55
58,5
50
Dimensions are in centimeters
C
d
e
F
G
Min
59,5
58,9
59,5
1,3
Fig. 1
Connection to the electrical power mains
The oven is only for domestic use.
The feed voltage and the absorbed power are as indicated on the data plate
attached to the left-hand side upright, which can be seen when the oven door is
open. Connecting must be carried out by qualified personnel and in accordance
with the regulations currently in force.
The manufacturer can not be held responsible for any damages to persons or
objects caused by failure to observe these instructions.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
The oven must be connected to the mains through a multipole circuit breaker with
a contact-to-contact gap of at least 3 mm, making sure that the earth wire is not
disconnected. For connecting use a flexible cable of the H05V2V2-F 3x1,5 mm
type remembering to make it long enough to allow the oven to be removed from its
housing unit when maintenance work is required.
To connect the cable to the oven
proceed as follows (see Fig. 2):
- Remove the lid (1) by unfastening
the three screws (2). Unfasten
the two screws (3) for the cable
holder and feed the cable through
the opening immediately below the
cover.
- Remove about 12 cm of the
outside insulation from the cable
and shorten the two active wires
(live and neutral) to 6 cm, leaving
long the one to be connected to
the main earth terminal on the
terminal box; remove about 1 cm
of the main insulation from the three wires and connect
H
the terminal box, remembering to respect the polarities.
86,5
- Tighten the two screws (3) of the cable holder and put the lid (1) back on with
the three screws (2).
WARnInG
This apparatus must be earthed.
Fig.
NL
FR
EN
2
DE
them correctly to
51