4.2.2 temperatura maintenance
to set a temperature maintenance cycle after a regeneration cycle or a new cycle, proceed
as follows.
if the appliance is switched off, turn it on using the switch-on button (2). press the key
Hold (10). on display will appear the maintenance temperature, tHat can be changed
using buttons 5 and 6. press the Start button (12). in case the chamber is not warm
enough (for example if the cycle is new) the regenerator will be set to pre-heating mode
and the display will showpre. once the temperature is reached, a beep indicates that you
can place the product in the regenerator. if upon appliance startup the chamber is already
warm, the unit will enter directly into maintenance mode, displaying the temperature of the
chamber. the maintenance cycle lasts until the operator commands the manual stop (key
12).
4.2.3 programming 2 regeneration phases and Hold (maintenance).
onlY proGrammaBle deViCes
if you have a programmable regenerator (fig. 12 page 11) you can program the unit to
automatically switch to maintenance mode once the regeneration cycle is completed. the
possible combinations provide the possibility to set up to two regeneration phases followed
by a Hold phase. set the regeneration parameters as shown in point 4.2.1 . during pa-
rameter setup, the led l1 near the display flashes. once the temperature, time / needle
probe temperature are set, press phase (3) to enter another regeneration phase and set
the regeneration parameters (chamber temperature and time/ core probe temperature). For
example it is possible to set a first regeneration phase at 130 ° C for 15 minutes followed
by another regeneration phase at 80 ° C with the core probe at 65 ° C.
in both cases, you can set the regeneration with one or two phases; if you want to append
a maintenance phase at the end of the regeneration cycle, press the button Hold (10) at
the end of phase one (if regeneration is with single-phase) or phase 2 (if regeneration is with
two phases) and proceed as shown in point 4.2.2 . in any case, the maintenance phase
must be set after the last phase. it is not possible to make a regeneration phase followed
by a maintenance phase followed by a regeneration phase.
the possible combinations are:
ex. 1: pHase 1  CooK + Hold
ex. 2: pHase 1  CooK + pHase 2  CooK
ex. 3: pHase 1  CooK + pHase 2  CooK + Hold