1.
enter -confirm- button (for programmable models only - fig. 12).
2.
appliance start button.
3.
phase button (for programmable models only - fig. 12).
4.
Book button (for programmable models only - fig. 12).
5.
Button for decreasing temperature.
6.
Button for increasing temperature.
7.
Humidification parameter setting button (range 0-10).
8.
time setting button (in regeneration set to 20 minutes) (in maintenance set to infi-
nite).
9.
regeneration parameter setting button; preset standard values equal to 140°C/160°C
(range 90/170°C).
10.
maintenance parameter setting button (range 25/100°C).
11.
Button for regenerator with needle probe (optional).
12.
maintenance start/stop button. With the appliance turned off, the red led is lit.
13.
Fan/fans speed setting button.
13a.
maximum fan speed.
13b. minimum fan speed.
l1
phase 1
l2
phase 2
4.2.1 setting a regeneration cycle.
switch on the board pressing the switch-on key (2). select the regeneration temperature
using button 9. the system prompts two default values (140°C / 160°C).
the keys 5 and 6 allow the user to change the set temperature to minimum 90°C and
maximum 170°C. press the humidity key (7) to set the degree of moisture. Use keys 5 and
6 to change this parameter between 0 and 10. press the clock key (8) to set the regenera-
tion time (default value 20 minutes). Use keys 5 and 6 to set the desired regeneration time.
For regeneration controlled by core probe, press the needle probe key (11) and change the
core temperature with keys 5 and 6. press the key Start (12), to enable the operation and
the device will be set to 'pre' or pre-heating. once the chamber preheating time elapses,
the appliance emits a sound signal. open the door, introduce the product to be regenerated
and close the door. the duration of regeneration process depends on the time selected. at
the end of this cycle of regeneration, the appliance emits again a beep and you can remove
the product or launch a temperature maintenance cycle. For models with programmable
board (fig.12 page 11) the regenerator can be programmed to switch automatically to
maintenance phase, after regeneration.